Toode Classic profile: measuring the lengths and installation
The video shows how to calculate the lengths needed for a Classic roof correctly and in what order it is installed.

The name “Classic” describes the classic design of this profile, which has been used for decades and is very popular throughout the Baltics. Classic panels join with a unique “Click” lock system, which keeps the joint between panels hidden. The Classic “Ekstra” version has two decorative ribs in the middle of the panel, giving the roof extra visual depth.
Uses of the Classic profile:
- Family houses
- Apartment buildings
- Holiday homes and summer cottages
- Saunas
- Public buildings
- Facade and wall cladding
The job of a roof is to protect the interior from the weather – rain, snow, sun, wind and temperature changes. The Classic profile does this with a hidden fixing system that prevents water getting in through screw holes, and with a durable polymer or metal coating that protects against corrosion.
The Classic profile is also available with a factory-applied sound-absorbing layer – Classic with SoundControl →
Installation summary
Installing the Classic profile is different from an ordinary profiled sheet – the hidden fixing system and thermal expansion compensation require the steps to be followed carefully. Below is a summary of the instructions. The full PDF instructions are available under the “Documents” tab.
Slight waviness of Classic and standing seam roof sheets is acceptable and does not in itself indicate a material defect. How noticeable it is can depend on several factors:
- Quality of the deck and battens. The battens must be built precisely, evenly and calibrated. Unevenness in the roof structure can also become visible in the finished roof surface.
- Quality of installation. The roof sheets must be installed according to the installation requirements. The fixings must not be overtightened, because steel needs to be able to expand and contract naturally with temperature.
- Steel thickness. A thicker steel sheet is usually stiffer and looks flatter. For example, 0.60 mm steel will be less prone to waviness than a thinner material.
- Surface coating. A matt, textured coating visually reduces light reflections and therefore also makes any waviness of the sheet less noticeable.
- Natural properties of steel. Internal stresses can arise in the sheet during production, transport, installation and use. Under temperature changes and mechanical loads, they can show as slight waviness of the sheet surface.
That is why the visual result of a Classic or standing seam roof depends not only on the material itself, but also on a correctly prepared roof structure, quality installation and the chosen steel thickness and coating.
Delivery and storage
When receiving the goods, check that all ordered materials have been delivered and that there is no transport damage. Report any damage to the seller immediately and note it on the delivery note. Damaged materials must not be installed!
- Store the panels on crossbeams at least 20 cm above the ground, protected from direct precipitation.
- Keep coloured panels in sealed packaging for no longer than 4 weeks.
- Galvanised panels in sealed packaging – for no longer than 1 week, because white rust can form in damp conditions.
Roof deck and battens
The Classic profile has strict requirements for the flatness of the battens: the deviation over a length of 5000 mm must not exceed 3 ‰ (1.5 mm). Uneven battens can stop the “Click” joints from locking and create a wavy surface.
- Underlay (breather membrane): required – it leads condensation out of the roof structure. Fix it horizontally to the rafters, then hold it down with counter battens (min. 22×50 mm, 32×50 mm recommended).
- Battens: dry timber battens of min. 22×100 mm (32×100 mm recommended).
Starter sheet and installing the panels
For the Classic profile, the eaves flashing (C) must be installed first. The straightness of its outer edge is critical – it determines the alignment of all rows of panels. It is best to install the gutter, or at least the gutter brackets, before the starter sheet.
- The panels are installed from right to left.
- The first panel must be fixed fully before the second panel is installed – the next panel covers the fixing screws of the first, and they can no longer be reached.
- The eaves edge of the panel is slid behind the starter sheet and secured – the eaves area is a double sheet without through-fixing screws.
- Each following panel is slid in next to the previous one, and the “Click” joint is pressed down by hand or with a soft-soled shoe, from the eaves towards the ridge.
- Only step on the flat parts of the panel, not on the seam.
Thermal expansion
Thermal expansion is an especially important consideration for the Classic profile: with a temperature difference of 60 °C, a panel can expand by up to 1 mm/m. An 8-metre panel can differ in length by ~10 mm between winter and summer.
- The side edges of the panels have factory-made slotted holes – the fixing screws must not be screwed “all the way” (down to the batten surface), because this blocks the expansion compensation and can deform the “Click” joint. Place each screw in the centre of the slot, so that the profile can move freely in both directions as it expands. Placing all the screws at one end of the slots, or in a mixed order, prevents thermal expansion and can cause buckling in the profile!
- The top end of the panel is not fixed to the top batten – it is left free to compensate for expansion upwards. The ridge support and ventilation element (B) is fixed only to the panel, not to the battens.
- It is best to install the panels without lengthwise joints. If joining is needed, use the extension (H); overlap – at least 250 mm; the joint must be over a batten; the joints must be staggered, no closer than 700 mm.
Screws and consumption
| Screw type |
Use |
Consumption |
| 4.2×25 mm small head, without sealing washer, stainless |
Fixing Classic panels to the battens (through the edge of the panel) |
~6 pcs/m² |
| 4.8×20 mm with sealing washer drill point, hot-dip galvanised |
Fixing flashings (sheets) to the panels |
~5 pcs/lm |
| 4.8×28 mm with sealing washer sharp point, hot-dip galvanised |
Fixing flashings to timber |
as needed |
Use tin snips or other non-abrasive tools for cutting. Never use an angle grinder with an abrasive disc – the sparks damage the coating and cause corrosion at the cut edges. Brush away metal filings immediately.
Installing the flashings
- Eaves flashing (C) – installed first, before the panels; the straightness of its outer edge is critical.
- Valley (G) – installed before the panels, from the bottom up; overlap at least 200 mm.
- Verge (D) – installed from the bottom up after the panels; overlap at least 50 mm.
- Ridge support and ventilation element (B) – fixed only to the panel, not to the battens; 20-30 mm from the outer edge of the ridge.
- Ridge (A) – installed last; overlap 100 mm; do not join in the overlap area.
Safety at work
Always wear work gloves, soft-soled shoes and thick work clothes. When lifting panels, make sure nobody is standing underneath. Never stop a sliding panel with your hand – this can cause serious cuts. Use roof ladders or a personal safety system to move around on the roof.