Roof ladders let you move safely on the roof for maintenance, chimney sweeping and other work, while wall ladders let you climb onto the roof from the ground. The TOODE ladder system is made of galvanised and powder-coated steel, is available in the same RR colours as the roof and has brackets for all metal roof profiles. We will help you put together the ladders and brackets for your building.
Roof ladder or wall ladder?
|
Roof ladder |
Wall ladder |
| Where it is installed |
on the roof slope from the eaves to the ridge |
on the building wall from the ground to the roof or a platform |
| Dimensions |
1200 × 450 mm or 3000 × 450 mm |
frames 1200 or 3000 mm, width 450 or 700 mm |
| Longer section |
frames are joined with M8 × 45 screws |
sections are joined to the length you need |
| Brackets |
to suit the profile, at least every 1400 mm |
pairs of wall brackets at least every 3000 mm |
| Accessories |
step for low-pitched roofs, platform |
hoops for the transition to the roof, safety cage, support plate for sandwich panels |
| View |
Roof ladders |
Wall ladders |
If you need to climb onto the roof from the ground, you usually need both: a wall ladder along the wall and a roof ladder on the roof slope, joined with ladder hoops.
Roof ladder brackets for every type of roofing
- For the tile profile and trapezoidal profile – the brackets are installed over the roof battens or another load-bearing structure, with protective seals underneath that protect the roofing surface.
- For the Classic profile – the bracket is fixed to the Classic seam with three counter plates, without drilling the roofing. The edges of the ladder are also supported by universal roof brackets, and ladders longer than 6 m need a middle bracket.
- For the standing seam profile – the bracket is fixed to the seam with a counter plate, also without drilling. The recommended screw tightening torque is about 35 Nm.
For all types of roofing, the distance between roof ladder brackets must not exceed 1400 mm. The ladders are suitable for TOODE metal roofing.
How to calculate the length of a roof ladder
Measure the roof slope
Measure the distance from the ridge to the eaves and subtract about 400 mm – this is the ladder length you need.
Choose the sections
The ladder frames are 1200 mm and 3000 mm long. If you need a longer ladder, several frames are joined – one frame slides into the other and they are screwed together.
Count the brackets
Brackets are fitted at least every 1400 mm. Also add steps for a low-pitched roof or a platform if needed.
Wall ladders and safety cage
Wall ladders are planned so that the top is about 100 mm above the eaves, the bottom rung is about 1100 ± 100 mm above the ground, and there is at least 200 mm clearance to the eaves or gutter. Where possible, wall brackets are fixed to the load-bearing structure of the building. On sandwich panel walls, a support plate is used.
A safety cage can be installed on taller ladders – it consists of 1200 mm high sections, and the bottom hoop is at a height of 2200-3000 mm. The cage can also be added later to an existing ladder. Whether it is needed depends on the height of the ladder, the building design and the safety requirements of the site.
The transition from the wall ladder to the roof is made with the upper and lower hoop set; wall brackets can also be ordered separately as a wall bracket set.
Material and colours
The ladder system components are made of steel with Z275 zinc coating and about 80 µm powder coating. They are available in the colours of the TOODE RR catalogue so the ladders match the roof, and in other shades to individual order. The wall ladders have a technical data sheet with testing to RT 85-11132 and EN 12951:2004.
For working safely on the roof, a roof walkway for moving along the roof and snow guards that stop snow from sliding off the roof are also useful.
Frequently asked questions
How do I choose the length of a roof ladder?
Measure the distance from the ridge to the eaves and subtract about 400 mm. Then choose 1200 mm or 3000 mm frames – if you need a longer ladder, several frames are joined.
Do I need to drill the roofing to install a roof ladder?
For Classic and the standing seam profile – no, the brackets are fixed to the seam with counter plates. On tile profile and trapezoidal roofs, the brackets are installed over the battens or another load-bearing structure, with protective seals underneath.
How often do ladder brackets need to be fitted?
For roof ladders, the distance between brackets must not exceed 1400 mm. For wall ladders, the distance between pairs of wall brackets is up to 3000 mm, but with a safety cage extra brackets may be needed.
What ladder sizes are available?
Roof ladders – 1200 × 450 mm and 3000 × 450 mm. Wall ladders – in 1200 mm and 3000 mm frames, 450 mm or 700 mm wide. Both types can be joined into longer ladders.
Does a wall ladder need a safety cage?
It depends on the height of the ladder, the building design and the safety requirements of the site. A modular safety cage can be added to TOODE wall ladders – either when the ladder is installed or later.
Can wall ladders be installed on sandwich panels?
Yes, there is a special support plate for 450 mm and 700 mm ladders. The fixing must be chosen to suit the specific panel and building structure.
What colours are roof ladders available in?
In the colours of the TOODE RR catalogue, the same as metal roofing, and in other powder coating shades to individual order.