A roof walkway is a safe path across the roof for maintenance, chimney sweeping and technical inspections. TOODE roof walkways come in 3000 mm and 1200 mm lengths, with brackets for all types of roofing and in the same RR colours as the roof.

If you have any questions about our products or about a professional roof, feel free to contact us. We will be happy to help!
Send us your roof plan and our specialists will reply with the best solution at the most reasonable cost.
Write a messageThe cart is empty.
A roof walkway is a safe path across the roof for maintenance, chimney sweeping and technical inspections. TOODE roof walkways come in 3000 mm and 1200 mm lengths, with brackets for all types of roofing and in the same RR colours as the roof.






The roof walkway bracket has to be chosen according to the roofing, so that the walkway holds securely and the roof is not damaged.
| Roofing | How it is fixed |
|---|---|
| Trapezoidal and other profiled metal roofs | universal bracket – the same system as for snow guards, with 6.5 × 38 mm screws and sealing washers |
| Tile profile | tile profile bracket with 6.5 × 38 mm screws with sealing rings, with roof walkway seals underneath |
| Classic | at the profile seam with a counter plate and M8 × 30 mm screws, without screwing through the roofing |
| Standing seam profile | on the seam with a counter plate, without screwing through the roofing |
| Clay and concrete tiles | hooked behind the roof structure and screwed to the batten |
| Asbestos-free slate (Eternit) | the end under the sheet to the structure, with 6.5 × 50 mm screws and a sealing washer |
In all systems, the walkway bracket is joined to the base bracket and the walkway itself with M8 × 30 mm screws. The installation is shown step by step on each product page.
For safe access to the roof, roof and wall ladders are also useful, and for winter – snow guards.
3000 mm and 1200 mm, in the colours of the TOODE RR catalogue, and in other colours to individual order.
A 3000 mm walkway needs 4 brackets, a 1200 mm walkway 2 brackets.
For Classic and the standing seam profile – no, the bracket is fixed to the seam with a counter plate. On trapezoidal, tile profile and slate roofs, the bracket is screwed on with roofing screws with sealing washers that seal the fixing point. On clay and concrete tile roofs, the bracket is screwed to the batten, and a hole is drilled in the tile above it and the tile is screwed on.
Yes. The roof walkway bracket has several fixing points, so the walkway can be fixed at the angle you need.