Trapezoidal profile TP45
Price from 9,92 € / m² incl. VAT8,20 € / m² excl. VAT
Excl. VATIncl. VAT
The price depends on the coating, material thickness and quantity ordered.
Hangar, TP45, RR33 Black See how it looks on a building TP45 in the roof visualiser - choose the colour, rainwater system and accessories.

The trapezoidal profile TP45 is the highest of the Toode trapezoidal profiles, with a deep 41 mm profile that gives an excellent load-bearing capacity and allows large rafter spacing. TP45 is the ideal solution for industrial, agricultural and public buildings where large areas need to be covered with as few battens as possible. The profile comes in three versions: TP45 R – for roofs, TP45 A and TP45 B – for walls.

Technical specifications of the trapezoidal profile TP45


Trapezoidal profile TP45 cross-section and dimensions

Use Roofing (R), wall cladding (A, B)
Material thickness 0,45–0,70 mm
Profile height 41 mm
Number of waves per sheet 6 waves
Cover width 900 mm
Coatings Galvanised, Polyester, Matt Pol, Pural BT, Pural BT Matt, PVDF
Minimum / maximum profile length 500–10 000 mm
Minimum roof pitch 10° (1:5.5 from horizontal)

TP45 profile versions

Version Use Description
TP45 R Roof Profile configuration optimised to drain rainwater down the roof slope
TP45 A Wall Wall cladding version for horizontal or vertical installation
TP45 B Wall Alternative wall version with a slightly different trapezoid configuration

General information

The deep 41 mm profile of TP45 gives a much higher load-bearing capacity than lower profiles – this allows wider batten spacing and fewer battens. That is why TP45 is the preferred choice for wide industrial hangars, agricultural buildings and warehouses, where using materials efficiently pays off.

Important: if TP45 is specified in a project, pay attention to the wave height and the number of waves per sheet when buying the material. There are different TP45 versions on the market with different dimensions – SIA Toode offers TP45 with six waves and a height of 41 mm.

The profile is available in thicknesses up to 0.70 mm, which matters for buildings with higher snow loads or wider rafter spacing. Choosing a thicker material makes the panel stiffer and increases the permitted batten spacing.

The main difference is the profile height and the resulting load-bearing capacity. TP20 is 18 mm high with a cover width of 1100 mm – suitable for standard buildings with normal batten spacing. TP45 is 41 mm high with a cover width of 900 mm – with a much higher load-bearing capacity and suitable for wider batten spacing. TP45 is often used for wide industrial buildings where TP20 is not enough.

There are different TP45 series profiles on the market with different dimensions – some manufacturers have a different number of waves or a different height. If the project specifies a particular number of waves or profile height, make sure the material you order meets these requirements. SIA Toode TP45 has 6 waves and a height of 41 mm.

Yes – the TP45 A and TP45 B versions are designed for wall cladding. The deep profile gives the facade a strong, industrial look typical of hangars and production buildings. There are no pitch requirements for wall cladding – the profile can be installed vertically or horizontally.

Yes – the SIA Toode TP45 profile has CE marking and a declaration of performance. The document can be downloaded under “Documents”.

A full set of flashings is available for installing the TP45 trapezoidal profile – sheet metal parts for the ridge, verges, eaves, valleys and wall abutments. All flashings are available in the colours of the Toode RR catalogue and are made from the same coated steel as the profile panels.

 

The main flashings

Roof ridge

Closes the top of a TP45 roof, keeping water, dust and insects out from under the roofing. Fixed to the tops of the profile waves with 4.8×28 mm screws with sealing washers, at a spacing of no more than 400 mm. Because of the deep TP45 profile, a ridge seal is also recommended on low-pitched roofs. Overlap – at least 100 mm.

Roof eaves flashing

Installed at the bottom edge of the roof before the profile panels. It leads water from the underside of the panels into the gutter and protects the boards from moisture. Fixed to the first batten at a spacing of no more than 500 mm. Eaves flashing overlap – 50 mm.

Verge

Closes the side edge of the TP45 profile, wrapping around the panel wave from the side. Because of the deep TP45 profile (41 mm), the verge is wider than for lower profiles. Fixed to the panel with 4.8×20 mm screws (spacing up to 800 mm) and to the board with 4.8×28 mm screws. Installed from the bottom up; overlap – at least 50 mm.

Valley

Keeps the roof watertight in the valley – where two roof slopes meet at an internal angle. Because of the high TP45 profile, the valley must be at least 300×300 mm in cross-section; 400×400 mm is recommended for complex valleys. Installed before the profile panels, from the bottom up; overlap – at least 200 mm. Under the valley there must be solid boarding at least 300 mm wide on both sides.

Abutment

Makes a watertight joint between a TP45 roof and a vertical wall – at a chimney, a higher wall or another perpendicular structure. The top edge of the sheet is inserted into a groove in the wall and filled with a durable sealant. Fixed to the panel with 4.8×20 mm screws at a spacing of up to 800 mm.

Fixing screws

Screw Use Consumption
4.8×28 mm with sealing washer sharp point, hot-dip galvanised Fixing TP45 panels to timber battens (through the bottom of the wave) ~6 pcs/m²
4.8×20 mm with sealing washer drill point, hot-dip galvanised Fixing flashings to the panels; joining panel overlaps ~5 pcs/lm
4.8×28 mm with sealing washer sharp point Fixing flashings to timber as needed

The installation principle and types of flashing are the same, but because of the deep TP45 profile (41 mm) the dimensions of some flashings differ. The verge, ridge and abutments are made to match the height of the TP45 profile. When ordering flashings, always say that they are for the TP45 profile.

Yes – flashings can be made to individual order in the exact length and configuration. A custom-made part is often more precise and cheaper than a standard-size part. Contact our sales department.

This profile is available in the coatings listed below. The properties of each coating – thickness, corrosion and UV resistance, galvanising and warranty – are compared under Metal roof coatings.

Colour chart

The table shows which colours each coating is available in. Colours on screen are approximate – for an exact choice, ask for physical colour samples.

RR11 - Dark green
RR20 - White
RR21 - Light grey
RR22 - Grey
RR23 - Dark grey
RR2H3 - Anthracite
RR25 - Yellow
RR28 - Dark red
RR29 - Red
RR30 - Beige
RR31 - Light brown
RR32 - Dark brown
RR33 - Black
RR35 - Blue
RR36 - Light green
RR37 - Green
RR40 - Silver metallic
RR41 - Dark silver metallic
RR750 - Brick red
Zn - Galvanised
AlZn - Aluminium-zinc
Printech Camo - PX131
Printech FineStone - PB074
Printech Wood - PW371
* Approximate colour samples

Colour / coating table

Polyester MATT POL PURAL BT PURAL MATT BT PVDF PVC Natural metal Printed
RR11 ● ●
RR20 ● ● ●
RR21 ● ● ●
RR22 ● ●
RR23 ● ● ● ● ●
RR2H3 ●
RR25 ●
RR28 ●
RR29 ● ●
RR30 ●
RR31 ●
RR32 ● ● ● ● ●
RR33 ● ● ● ● ●
RR35 ●
RR36 ●
RR37 ●
RR40 ● ●
RR41 ● ●
RR750 ● ●
Zn ●
AlZn ●
Printech Camo ●
Printech FineStone ●
Printech Wood ●

Galvanised steel is the most cost-effective choice for economical industrial buildings. If a colour is needed, Polyester is the standard choice, while Matt Pol gives a matt look with better corrosion resistance. Pural BT or Pural BT Matt is recommended if the building is in an aggressive, corrosive environment or is planned for a long lifespan without recoating.

Yes – PVDF coating is available for the TP45 profile only in the metallic shades RR40 (Silver Metallic) and RR41 (Dark Silver Metallic). If you need PVDF in another colour, contact our sales department.

It depends on the coating: Polyester and Matt Pol – from 0 °C; Pural BT and Pural BT Matt – from -15 °C; PVDF – from -10 °C. Galvanised steel has no coating temperature limits.

PVDF is produced in a limited range of colours – the standard range includes only the metallic shades RR40 and RR41. If you need PVDF in another colour, contact our sales department.

An individual order is possible in some cases. Contact our sales department with the colour code you want.

In this section you will find the TP45 declaration of performance, guidelines for receiving and storing materials, and a document on storing galvanised steel. Most documents are in Latvian.

Declaration of performance (DoP) – TP45

The CE marking document confirming that the TP45 profile complies with European construction standards. The declaration lists the main performance characteristics of the material and the scope of the manufacturer’s responsibility. Needed for the technical documentation of the project and for building permit applications.

Download DoP TP45 (PDF) →

Information on receiving and storing products

The document describes how to receive the delivered profiles correctly, what to check on delivery and how to store the material before installation. Note: keep coloured panels in sealed packaging for no longer than four weeks; galvanised panels outdoors – for no longer than one week.

Download the guidelines (PDF, LV) →

“White rust” on galvanised steel

A document on how white rust forms on galvanised steel, how to prevent it and what to do if it appears. Especially important if you have chosen the galvanised TP45.

Download the document (PDF, LV) →

Yes – the SIA Toode TP45 profile has CE marking and a declaration of performance. The document can be downloaded above in this section.

Yes, provided that the installation is carried out according to the Toode guidelines – the right screws with EPDM sealing washers, the correct overlap and no abrasive cutting tools.

The TP45 R version is used for roofs, the TP45 A and TP45 B versions for walls. The deep profile of TP45 (41 mm) gives a much higher load-bearing capacity than lower profiles, which allows wider batten spacing. This makes TP45 the preferred choice for wide industrial hangars, agricultural buildings, public buildings and warehouses.

Uses of the TP45 profile:

  • Industrial and production buildings
  • Agricultural buildings and hangars
  • Public buildings with large roof spans
  • Warehouses and logistics centres
  • Wall cladding (A, B versions)

Important: if TP45 is specified in a project, check the number of waves and the profile height before ordering – SIA Toode TP45 has six waves and a height of 41 mm. There are also other TP45 versions on the market with different dimensions.


Installation summary

Installing TP45 is similar to installing TP20, but because of the deep profile a few differences must be taken into account – especially the batten spacing and the size of the flashings. Below is a summary of the main installation stages.

Delivery and storage

When receiving the goods, check that all ordered materials have been delivered and that there is no transport damage. Report any damage to the seller immediately. Damaged panels must not be installed!

  • Store the panels on crossbeams at least 20 cm above the ground.
  • Coloured panels in sealed packaging – for no longer than 4 weeks.
  • Galvanised panels in sealed packaging outdoors – for no longer than 1 week.
  • Always lift the panels – never drag them. The sharp edges can damage the coating of the panel underneath.

Roof deck and battens

  • Underlay (breather membrane): required for all insulated metal roofs. Fix it horizontally to the rafters, then hold it down with counter battens (min. 25×50 mm, 32×50 mm recommended).
  • Battens: min. 22×100 mm (32×100 mm recommended) dry timber. Nail with hot-dip galvanised nails – at least 2 nails at each crossing point.
  • TP45 batten spacing: depends on the material thickness, the roof pitch and the snow load. Because of the deep TP45 profile, the permitted batten spacing is much larger than for TP20 – the exact spacing must be set according to the project or in consultation with our specialists.
  • In valleys there must be solid boarding at least 300 mm wide on both sides of the valley.

Eaves flashing and installing the sheets

  • Before the panels, install the eaves flashing at the bottom edge of the roof and, preferably, the gutter too.
  • The panels can be installed either from left to right or from right to left. When starting from the right, each following panel lies on top of the previous one, which makes it easier to keep them parallel to the bottom edge.
  • First fix the first two panels with one screw each, align the bottom edge parallel to the eaves batten, then screw them down fully.
  • Side overlap – one wave. If the pitch is lower than standard, a sealant or sealing tape must be used in the side overlap.
  • Lengthwise, panels are joined with an overlap of at least 200 mm; stagger the joints.
  • Only step on the bottom of the wave, as close to the batten as possible – never on the top of the wave.

Screws and fixing rules

Screw type Use Consumption
4.8×28 mm with sealing washer Fixing panels to timber battens (through the bottom of the wave) ~6 pcs/m²
4.8×20 mm with sealing washer Fixing flashings to the panels; joining panel overlaps ~5 pcs/lm

Use tin snips or other non-abrasive tools for cutting. Never use an angle grinder with an abrasive disc – the sparks damage the coating and cause corrosion at the cut edges. Brush away metal filings immediately after cutting.

The installation principle is identical – screws through the bottom of the wave, underlay, battens and flashings. The main differences are: (1) TP45 allows wider batten spacing because of its higher load-bearing capacity; (2) the flashings are larger to match the 41 mm profile height.

It depends on the coating: Polyester and Matt Pol – from 0 °C; Pural BT and Pural BT Matt – from -15 °C; PVDF – from -10 °C. Galvanised steel has no coating temperature limits.