Wall ladder bracket support plate for sandwich panels

The wall ladder bracket support plate is designed for installing TOODE wall ladders (450 mm and 700 mm) on the surface of sandwich panels and other wall claddings. It forms a stable base for fixing the ladder wall bracket to the building facade.

The solution is especially suitable for industrial, warehouse and production buildings where sandwich panels are used for the facade and documented performance of the ladder fixing is needed.


Wall ladder bracket support plate for sandwich panels

TOODE wall ladder bracket support plate for sandwich panels.


Using the support plate on sandwich panels

The support plate is installed between the wall ladder wall bracket and the surface of the sandwich panel or other wall cladding. The plate is fixed to the ladder wall bracket with two M8 × 25 screws and nuts, and to the sandwich panel with 14 suitable sharp-point screws.


Installation diagram of the wall ladder support plate on a sandwich panel

The diagram shows a wall ladder installed on a sandwich panel using support plates. Click on the picture to enlarge it.

  • Maximum vertical distance between support plates: 1500 mm
  • Distance of the ladder frame from the wall: 200-300 mm
  • Connection of the support plate to the ladder wall bracket: 2 pcs M8 × 25 screws with nuts
  • Connection of the support plate to the sandwich panel: 14 pcs sharp-point screws suitable for the specific panel

During installation, the joint between the support plate and the wall cladding must be made watertight, so that moisture does not get into the wall structure.



Wall ladder with support plates on a different wall finish

Example of a wall ladder installed with support plates on a different wall finish. Click on the picture to enlarge it.

Can also be used on other facades

The support plate is not only for sandwich panels – according to the TOODE installation instructions it can also be used on other wall claddings and facade solutions.

The picture shows an example where a wall ladder with support plates is installed on a different wall finish. The exact wall structure cannot be determined from the picture alone, so the fixings for a specific site must always be chosen according to the actual wall material and load-bearing structure.

When installing on a different facade, keep in mind:

  • use fixings suitable for the specific wall structure;
  • where possible, fix to the load-bearing structure of the building;
  • check the stability and load-bearing capacity of the whole ladder and fixing set;
  • make the fixing points watertight;
  • follow the requirements of the building project and the site.

The 2.6 kN static load resistance declared in the technical data sheet applies to the support plate. The load-bearing capacity of the specific wall, the chosen screws and the whole connection must be assessed separately.


Tested fixing solution

In the support plate test carried out by TOODE, a sandwich panel made by Balex was used. The plate was fixed to the panel with 14 Würth RST stainless steel 6 × 25 mm fine-thread sharp-point screws (TOODE product No. 020106025). This installation met the requirements for wall ladders in the test.

On a specific site, the suitability of the screws and the fixing solution must be checked according to the structure of the sandwich panel used, the panel manufacturer’s instructions, the loads and the building project.

Planning a wall ladder for an industrial building?

Send us information about the wall structure of the building, the ladder height and the planned fixing point. TOODE specialists will help you find the right ladder and fixing set for the site.

Contact our sales team →


Technical data

  • Manufacturer: Toode
  • Product identification: wall ladder bracket support plate, 621410-621541
  • Intended use: for fixing wall ladders used to access the roof of a building or another platform
  • Material: S350GD + Z275
  • Thickness: 1.5 mm
  • Width: 165 mm
  • Length: 450 or 700 mm
  • Zinc coating: Z275
  • Powder coating thickness: about 80 µm
  • Static load resistance of the fixing: 2.6 kN
  • Reaction to fire: class A1
  • External fire performance: deemed to satisfy class Broof

Technical data sheet for industrial projects

A TOODE technical data sheet is available for the product, giving the product identification, intended use, material, dimensions, test standard and declared performance. The support plate was tested according to RT 85-11132.

In industrial projects, the technical data sheet helps the designer, contractor and client check the parameters of the chosen product and agree the solution with the requirements of the specific site. It does not replace an assessment of the load-bearing capacity of the specific wall structure and fixing.


Important installation conditions

  • Before installation, check the stability of the whole ladder system and the load-bearing capacity of the chosen fixing solution.
  • Follow the requirements of the specific sandwich panel manufacturer and the fixing solution specified in the building project.
  • If the site has additional requirements for wall ladder fixings, they must be followed.
  • The fixing points must have a watertight connection to the wall cladding.
  • The vertical spacing of the support plates must not exceed 1500 mm.

Need help fixing a wall ladder to sandwich panels?

Contact our sales team →

See TOODE roof and wall ladder solutions:

Roof and wall ladders →

Need a ladder wall bracket set?

Wall bracket set →

Need a wall ladder safety cage?

Safety cage for 450 mm ladders →

The support plate is for installing TOODE wall ladder wall brackets on the surface of sandwich panels and other wall claddings. It forms a base for fixing the ladder bracket to the facade.

The support plate is 165 mm wide and available in 450 or 700 mm lengths. The material thickness is 1.5 mm.

The support plate is made of S350GD steel with Z275 zinc coating and a powder coating layer about 80 µm thick.

The plate is fixed to the ladder wall bracket with two M8 × 25 screws and nuts, and to the sandwich panel with 14 sharp-point screws suitable for the specific panel. The fixing points must be watertight.

The vertical spacing of the support plates, i.e. the distance between pairs of ladder wall brackets, must not exceed 1500 mm.

According to the TOODE installation instructions, the ladder frame must be 200-300 mm from the wall.

The TOODE technical data sheet declares a static load resistance of 2.6 kN for the fixing. The total load-bearing capacity on a specific site also depends on the sandwich panel, the screws, the wall structure and the installation solution.

The TOODE test used a sandwich panel made by Balex and 14 Würth RST stainless steel 6 × 25 mm fine-thread sharp-point screws. This installation met the requirements for wall ladders in the test. For a different panel, the suitability of the fixing must be checked separately.

Yes. The technical data sheet gives the product identification, intended use, material, dimensions, test standard and declared performance. This is especially useful for designing industrial buildings and agreeing technical documentation.

The technical data sheet gives reaction to fire class A1 and external fire performance deemed to satisfy class Broof.