Solar panel mount for the standing seam profile

Solar panel mount for standing seam metal roofs. The mount is fixed onto the standing seam with a counter plate and two M8 screws, so the roofing is not drilled and the roof stays watertight. Aluminium rails for the solar panels are installed on the mounts.

Technical data

Parameter Value
Roofing standing seam metal roof
Fixing on the standing seam with a counter plate, without drilling the roofing
Screws 2 × M8×25 mm with nuts, tightening torque no more than 13 Nm
Design pull-out load (perpendicular to the axis) 5,09 kN
Design shear load (along the axis) 2,55 kN
Distance between brackets no more than 1100 mm

Set contents

Standing seam solar panel mount set: mount, counter plate, M8 screws and nuts

  • A – solar panel mount
  • B – counter plate
  • C – screw M8×25 mm, 2 pcs
  • D – nut M8, 2 pcs

Installation on a standing seam roof

  1. Place against the seam

    The mount (A) is placed against one side of the standing seam, and the counter plate (B) on the other.

  2. Tighten the screws

    The mount and counter plate are clamped together with two M8×25 mm screws (C) and nuts (D), tightening both screws evenly. Tightening torque – no more than 13 Nm; the mount must not deform.

  3. Install the rails

    The mounts are placed in a row at a spacing of up to 1100 mm, and the aluminium rails are screwed to their loops.

Important: do not tighten the screws with an impact driver or a drill in hammer mode. Use a torque wrench so as not to exceed 13 Nm.

Standing seam solar panel mount installation diagram: mount and counter plate on the standing seam

Left – the mount parts before installation, right – the mount tightened on the standing seam.

Installing the rails

Aluminium rails are installed on the mounts, and the solar panels are then fixed to them. The rail is screwed to the mount loop with a T-bolt and nut. The rails and their connectors are not included in the mount set.

The manufacturer’s installation instructions specify:

  • the first mount – no more than 300 mm from the end of the rail;
  • distance between mounts – no more than 1100 mm;
  • the rails are joined with a splice, and end caps are fitted at the rail ends;
  • because of the thermal expansion of metal, the total length of rails joined in one row – no more than 15 m.

Solar panel rail on the mounts: max 300 mm from the rail end, max 1100 mm between mounts

Mount spacing on the rail.

Joining aluminium rails: rail (A), splice (B) and end cap (C)

Joining the rails: A – aluminium rail, B – splice, C – end cap.

The number and position of mounts for a specific roof are determined by the solar panel system designer or installer, taking into account the weight of the panels and the wind and snow loads. If you use rails from another system, also follow the rail manufacturer’s instructions.

Which mount suits your roof?

Each metal roof profile has its own mount. All mounts are designed for aluminium rails, with a spacing of up to 1100 mm.

Roofing Fixing Pull-out* Shear*
Classic profile on the seam with a counter plate, without drilling 1,96 kN 2,15 kN
Standing seam profile (this page) on the standing seam with a counter plate, without drilling 5,09 kN 2,55 kN
Tile profile to two battens, 2 screws with sealing washers 6,00 kN 7,00 kN
Trapezoidal profile to the batten (2 screws) or on the crest (4 screws) 6,00 / 2,60 kN 8,00 / 4,10 kN

* Design load per mount: pull-out – perpendicular to the mount axis, shear – along the axis. Trapezoidal profile: installation to the batten / on the profile crest.

Maintenance

The mounts will last a long time if they are installed according to the instructions and checked regularly:

  • check the joints and the tightness of the screws;
  • touch up any worn paint or galvanising with touch-up paint;
  • replace mechanically damaged parts;
  • regularly clear leaves, needles and other debris from around the mounts and under the panels.

No. The mount and counter plate are clamped around the standing seam with two M8 screws that do not go into the roof sheet. The roofing stays intact and watertight.

No more than 13 Nm. Tighten both screws evenly with a torque wrench, not in impact mode – a mount tightened too much can deform and crush the seam.

The design load of one mount is 5.09 kN pull-out (perpendicular to the axis) and 2.55 kN shear (along the axis). The load-bearing capacity of the whole system depends on the number and position of the mounts on the roof.

The first mount is installed no more than 300 mm from the end of the rail, then every 1100 mm at most. For example, a 4.8 m rail needs at least 5 mounts. The exact number for a specific roof is determined by the solar panel system installer, taking into account the wind and snow loads.

No. The Classic profile seam has a different shape, so it has a separate Classic mount with a wedge-shaped counter plate.

No. The set contains the mount and its installation parts. The aluminium rails, their connectors and panel clamps must be bought separately.