Solar panel mount for tile profile metal roofs. The long mount spans the step of the profile, and both its ends are screwed through the roof sheet to two battens. The load from the panels is transferred directly to the roof structure, so the design load of the mount is 6.00 kN pull-out and 7.00 kN shear.

Technical data

Parameter Value
Roofing tile profile metal roof
Fixing in the bottom of the profile wave, through the sheet to two battens
Screws 2 × 6.5×40 mm with sealing washer
Design pull-out load (perpendicular to the axis) 6,00 kN
Design shear load (along the axis) 7,00 kN
Distance between brackets no more than 1100 mm

Set contents

Tile profile solar panel mount set: mount and screw with sealing washer

  • A – solar panel mount
  • B – screw 6.5×40 mm with sealing washer, 2 pcs

Installation on a tile profile roof

  1. Place over the battens

    The mount (A) is placed along the roof slope in the bottom of the profile wave so that both its ends are over the battens.

  2. Screw to the battens

    Each end of the mount is screwed through the roof sheet into the batten with a 6.5×40 mm screw with sealing washer (B).

  3. Install the rails

    The mounts are placed in a row at a spacing of up to 1100 mm, and the aluminium rails are screwed to their loops.

Important: do not tighten the screws in impact mode and do not overtighten them – the sealing washer must seat properly but must not be damaged.

Tile profile solar panel mount installation diagram: mount screwed to two battens

Top – the mount along the roof slope, screwed to two battens. Bottom – cross-section: the mount in the bottom of the profile wave.

Installing the rails

Aluminium rails are installed on the mounts, and the solar panels are then fixed to them. The rail is screwed to the mount loop with a T-bolt and nut. The rails and their connectors are not included in the mount set.

The manufacturer’s installation instructions specify:

  • the first mount – no more than 300 mm from the end of the rail;
  • distance between mounts – no more than 1100 mm;
  • the rails are joined with a splice, and end caps are fitted at the rail ends;
  • because of the thermal expansion of metal, the total length of rails joined in one row – no more than 15 m.

Solar panel rail on the mounts: max 300 mm from the rail end, max 1100 mm between mounts

Mount spacing on the rail.

Joining aluminium rails: rail (A), splice (B) and end cap (C)

Joining the rails: A – aluminium rail, B – splice, C – end cap.

The number and position of mounts for a specific roof are determined by the solar panel system designer or installer, taking into account the weight of the panels and the wind and snow loads. If you use rails from another system, also follow the rail manufacturer’s instructions.

Which mount suits your roof?

Each metal roof profile has its own mount. All mounts are designed for aluminium rails, with a spacing of up to 1100 mm.

Roofing Fixing Pull-out* Shear*
Classic profile on the seam with a counter plate, without drilling 1,96 kN 2,15 kN
Standing seam profile on the standing seam with a counter plate, without drilling 5,09 kN 2,55 kN
Tile profile (this page) to two battens, 2 screws with sealing washers 6,00 kN 7,00 kN
Trapezoidal profile to the batten (2 screws) or on the crest (4 screws) 6,00 / 2,60 kN 8,00 / 4,10 kN

* Design load per mount: pull-out – perpendicular to the mount axis, shear – along the axis. Trapezoidal profile: installation to the batten / on the profile crest.

Maintenance

The mounts will last a long time if they are installed according to the instructions and checked regularly:

  • check the joints and the tightness of the screws;
  • touch up any worn paint or galvanising with touch-up paint;
  • replace mechanically damaged parts;
  • regularly clear leaves, needles and other debris from around the mounts and under the panels.

The screws go into the bottom of the profile wave over the batten – in the same way as the tile profile sheets themselves are fixed to the battens. Each screw has a sealing washer that seals the hole. It is important not to tighten the screws in impact mode and not to overtighten them, so that the sealing washer is not damaged.

So that it can be screwed to two battens at once. The load from the panels is spread over two battens, so the design load of the mount is 6.00 kN pull-out and 7.00 kN shear.

The first mount is installed no more than 300 mm from the end of the rail, then every 1100 mm at most. For example, a 4.8 m rail needs at least 5 mounts. The exact number for a specific roof is determined by the solar panel system installer, taking into account the wind and snow loads.

No, this mount is designed for tile profile metal roofs. For solutions for other roofing, contact us.

No. The set contains the mount and its installation parts. The aluminium rails, their connectors and panel clamps must be bought separately.